For a gas vent or type l vent this height must be 2 ft 0 61m or more.
Gas roof vent height.
Clearance in accordance with local installation codes and the requirements of the gas supplier 5 a 3 feet 91cm within a height of 15 feet 4 5m above the meter regulator assembly 5 b 3 feet 91cm above if within 10 feet 3m horizontally.
Notice that we use the words any roof surface or an part of a structure in this explanation.
3 16 diameters feature twist lock fittings screws required for 14 and larger diameters.
Round type b gas vent 18 3.
All other gas vents shall terminate not less than 2 feet 610 mm above the highest point where they pass through the roof and at least 2 feet 610 mm higher than any portion of a building within 10 feet 3048 mm.
Aluminum 016 inner wall galvanized 021 outer wall.
Gas vents that are over 12 inches 305 mm in size or are located less than 8 feet 2438 mm from a vertical wall or similar obstruction shall terminate not less than 2 feet 610 mm above the highest point where they pass through the roof and not less than 2 feet 610 mm above a portion of a building within 10 feet 3048 mm horizontally.
Round type b gas vent 10 16.
Aluminum 020 inner wall galvanized 021 outer wall.
Clearances 1 clearance to combustibles in single and multi family dwellings.
Aluminum 012 inner wall galvanized 018 outer wall.
Manufacturers recommendations usually take precedence over local building codes but you won t know for sure which takes precedence or what those manufacturers recommendations are.
The 2 10 rule states that combustion vents should terminate at least 2 feet above any part of the roof within 10 feet.